LifeGard V PASS Devices Recalled
The Safety Equipment Institute (SEI)
of McLean, Va., in cooperation with Allen Telecom Inc.,
Cleveland, Ohio, is recalling 1,459 LifeGard V PASS devices,
Model R500. The recalled units have a production date of
March 14, 1997, or later. There have been no reported
injuries or fatalities involving these devices. The recall
is being conducted to prevent the possibility of injury.
These devices failed to meet the
requirements set forth in NFPA 1982, Personal Alert Safety
System for Fire Fighters (1993), for Section 5-7, Impact
Resistance Requirements in the Cold Condition. The
requirement for testing in the cold condition is that the
sample PASS device be exposed to a temperature of minus 40
degrees, set in the automatic mode, and dropped eight times
onto a concrete surface from a height of three meters.
Following each drop, the sample unit should remain
motionless, and should sound the pre-alert and alarm signals
to determine the proper functioning.
SEI is a private, nonprofit
organization that administers third-party certification
programs to test and certify these PASS devices in
accordance with the NFPA standard.
Fire Departments using these recalled
devices should contact Allen Telecom at (800) 959-1585, or
(956) 630-1585, for instructions on returning their PASS
devices.
|